7

Connect tester (02)201 589 13 21 00 to vacuum element and activate vacuum.

8

Pull control pressure cable up to full load stop.

9

Measure dimension "a" between face of control pressure valve (46) and connecting plate (84).
Dimension "a" =  7mm 6-cylinder engines

6mm 8-cylinder engines

10 Dimension "a" can be set with hex. head socket screw (arrow) (Fig. item 7).

11 Testing program selector switch

Torque Converter > < Throttle Valve Cable/Linkage, A/T|Adjustments|Page 5209