300E (124.030) L6-3.0L (103.983) (1986)
7
Connect tester (02)201 589 13 21 00 to vacuum element and activate vacuum.
8
Pull control pressure cable up to full load stop.
9
Measure dimension "a" between face of control pressure valve (46) and connecting plate (84).
Dimension "a" = 7mm 6-cylinder engines
6mm 8-cylinder engines
10 Dimension "a" can be set with hex. head socket screw (arrow) (Fig. item 7).
11 Testing program selector switch