mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Emergency Tensioning Retractor DTC Readout 10|Page 9304 > < Emergency Tensioning Retractor DTC Readout 10|Page 9302
Page 1
background image

Seat Belt Control Module: Description and Operation

This article applies to vehicles as of 09/87:
The control unit, also referred to as the triggering unit or crash sensor, is responsible for determining the severity of a collision and, if necessary,
triggering the restraint system at the correct time.

General:

12-pin Control Unit, Driver Airbag

16-pin Control Unit, Driver/Passenger Airbag

As of 09/87, the airbag restraint system has a new control unit with integral reserve power source and voltage transformer. This means that the reserve
power source and voltage transformer previously accommodated in separate housings are no longer required.

Function:

The control unit processes the vehicle deceleration during a frontal collision and is rigidly coupled on a support bracket with the transmission tunnel of
the vehicle (as before). By means of an integral safety switch which interrupts the ignition circuits for the driver airbag and belt tensioner restraint
system during normal driving, the airbag and belt tensioners can only be triggered by an actual acceleration. This prevents any malfunctions.

An acceleration sensor installed in the control unit detects the deceleration acting on the vehicle in the longitudinal direction and sends an
appropriately conditioned signal to the trigger switches for evaluation. If the fixed triggering thresholds of both trigger switches are exceeded, the
output stages are activated as is appropriate for the circumstances detected via the belt buckle switch (buckle latch in/not in belt buckle) This results in
triggering of the system (see table below). If the power supply is interrupted during a collision, the driver airbag can still be triggered within 100 ms,
but not the two belt tensioners. The warning lamp lights up if the vehicle voltage is < 9.5 V for longer than 10 s. The lamp goes out at a voltage > 10 V
.

The housing and the electrical connections have been designed in such a way as to virtually exclude malfunctions due to electrical interference in the
vehicle electrical system caused by the switching of electric consumer units on and off, and by electromagnetic radiation on public highways.

In order to detect whether the buckle latches are inserted in the belt buckles or not, new belt buckles with separate switches and resistors were
necessary. This results in the triggering logic listed below.

Emergency Tensioning Retractor DTC Readout 10|Page 9304 > < Emergency Tensioning Retractor DTC Readout 10|Page 9302