Page 2
background image

4. Set selector lever to "P".
5. Unscrew retaining bolts (7) and remove shift valve housing (A).

Installation Note

The three bolts (7a) are 50 mm, the others are 55 mm long. Tightening torque 8 Nm.

Ensure that the range selector valve (A1) engages in the driver (arrow).

6. Unscrew bolts (arrows). Remove valves (13, 24, 86) and strainer (33a).
7. Hold shift valve body (A) and damper housing (B) together and turn over.

A Shift valve housing