300SD (126.120) L5-3.0L DSL Turbo (617.951) (1982)
Blower Motor Resistor: Service and Repair
Removal
1
Remove vacuum line (73) on brake assembly.
2
Loosen cable strap (arrow) and push vacuum line through bracing wall.
3
Detach vacuum distributor (see arrow) on nonreturn valves (74).
4
Loosen bayonet lock on non-return valves (74) and pull valves out of bracing wall.