mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Vacuum Pump, Diesel|Service and Repair > < Double Diaphragm Type|Page 2153
Page 1
background image

Vacuum Pump: Testing and Inspection
Single Diaphragm Type

1.

Using fabricated adapter, connect suitable vacuum gauge to vacuum line between brake booster and check valve.

2.

Start engine and run at 750 RPM and note length of time required to obtain 14.8 inches Hg vacuum.

3.

On models equipped with 9 or 10 inch single diaphragm brake booster, elapsed time should measure 15-18 seconds with brake unit and all
vacuum accessories vented and 10-13 seconds with brake unit only vented. On models equipped with 9 inch double diaphragm brake booster,
elapsed time should measure 25-26 seconds with brake unit and all vacuum accessories vented and 17-18 seconds with brake unit only vented.

4.

On all models, if elapsed time is not within specifications or if vacuum drops more than 5.9 inches Hg in 30 seconds, check vacuum system for
leaks. If no leaks are found, repair or replace vacuum pump as necessary.

Vacuum Pump, Diesel|Service and Repair > < Double Diaphragm Type|Page 2153