mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Torque Converter > < Vehicles With Program Selector Switch|Page 3493
Page 3
background image

4

Fit cap (12).

CAUTION: Risk of water penetration!

5

Pull out valve (2) using a hook until it engages in the assembly position.

6

Hook control pressure cable with vacuum element into transmission and install. Ensure that it is correctly engaged!

Checking Upshift Delay

1

Connect the two vacuum lines to upshift delay switchover valve (Y3/3). Upshift delay is activated.

2

Check on a road test in selector lever position "D" and low throttle.

NOTE:

-

Turn adjusting screw (11) clockwise: shift point at lower speed.

-

Turn adjusting screw (11) anti-clockwise shift point at higher speed.