mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 5846 > < Diagram Information and Instructions|Page 5844
Page 7
background image

Function selection "b" top and bottom (overall ventilation):
Blower starts after approx. 10 seconds, also below 35 °C coolant temperature. In position "AUTOM" in stages 3 to 5. Refrigerant compressor is
switched on. If function selection "a" or "b" is pressed with the ignition switched on, and the system is then switched to "c" or "d", the blower remains in
operation even at coolant temperatures below 33 °C.

In heating range air is routed to windshield, to side vents and to footwell; in coaling range additionally to air inlets in center of instrument panel.

The interior of the vehicle is extensively cooled free of draft, the footwell is cooled more intensively. This function serves the purpose of removing fog,
if any, on glass during damp, cold weather conditions.

3

Temperature dial

4

Push-button switch unit with 5 functions

5

Blower switch with 3 functions

Function selection "a" (defrosting):
With the ignition switched on, the blower will start immediately and operates in 6th blower stage only.

Max. heated air is routed to the windshield regardless of the setting of the temperature selector.

The recirculating pump always runs at the same time and the refrigerant compressor is switched on.

Blower switch (5):
The blower operates in 6 stages.

Diagram Information and Instructions|Page 5846 > < Diagram Information and Instructions|Page 5844