Receiver Dryer: Pressure, Vacuum and Temperature Specifications

Data:

Version 
-

Steel housing with sight glass

Contents 
-

0.54 L

Pressure relief valve starting 10/81 
-

Closes at max. 5 bar below opening pressure

Temperature switch in receiver dehydrator (starting 11/81)
-

Cut-in point 62°C or 52°C ± 3 °C.

-

Temp. tolerance 7° - 12 °C.

Pressure switch in receiver dehydrator
-

Cut-out pressure 2 ± 0.2 bar gauge pressure

-

Cut-in pressure max. 0.6 bar above cut-out pressure