mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Checking and Correcting Refrigerant Level|Page 1775 > < Refrigerant|Capacity Specifications|Page 1772
Page 1
background image

Refrigerant: Service and Repair
Checking and Correcting Refrigerant Level

Checking and Correcting Refrigerant Level

1

Clean sight glass on receiver.

2

Disconnect plug from refrigerant temperature sensor for air conditioning (B10/8) and bridge plug from temperature sensor (B10/8).

3

Allow engine to idle, switch on automatic climate control (DEF).

4

Observe sight glass and simultaneously remove bridge plug from refrigerant temperature sensor for air conditioning (B10/8).

The refrigerant must rise shortly after switching on the electromagnetic charge and then flow without any bubbles (i.e. coolant no longer visible).

NOTE:  It is not possible to check the capacity exactly at the sight glass. At higher ambient temperatures (>35 °C) some bubbles may appear even with
the correct capacity.

In the event of refrigerant loss or suspected leaks in the system, the correct capacity is only ensured after completely emptying (recycling) and refilling
the system, after checking the system for leaks. A correct capacity can only be achieved by weighing the refrigerant or by the use of a filling cylinder or
automatic air conditioner filling equipment.

NOTE:  Note the latest information concerning correct capacity

Checking and Correcting Refrigerant Level|Page 1775 > < Refrigerant|Capacity Specifications|Page 1772