3. Pull off cover (75) above regulating linkage of footwell flaps.
4. Pull off vacuum line (refer to arrow) and remove clamp (76) from actuating rod (72) by means of a screwdriver.
5. To remove vacuum element (39) for leg room flaps 1st version, lift off locks (73) by means of a screw-driver. On 2nd version, remove vacuum
element (39) from bayonet lock by a turning motion.