7.

Stop engine.

8.

Using air conditioning service equipment, evacuate R12 refrigerant at high-and low-pressure sides (A, Figure 2 and B, Figure 3) of A/C system for
45 minutes.

Note:

A/C service equipment should be able to pull at least 29.2" of vacuum.

9.

Refill recycled R12 once again into A/C system.

10.

Operate A/C system again, as in above steps 1-7 for approx. 10 minutes.

CAUTION!

Should the A/C compressor become noisy, stop engine and continue with "D. Replacing Receiver/Drier".

11.

Using air conditioning service equipment, evacuate the R12 at high- and low-pressure sides (A, Figure 2 and B, Figure 3) of A/C system for 45
minutes.

Note:

A/C service equipment should be able to pull at least 29.2" of vacuum.

CAUTION!

At this point, R12 is not to be used in A/C system again.

D. Replacing Receiver/Drier

Please see SMS (beige microfiches), Repair Instructions, Job No 83-540.

E. Installation of Service Valves