mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Cold Start Injector > < Mixture Control Unit
Page 1
background image

Air Flow Meter/Sensor: Service and Repair
Replacement

Air Flow Sensor Plate Adjustment

1.

Remove the air cleaner assembly.

2.

Remove the sensor plate stop bracket.

3.

Heat the sensor plate mounting screw with a heat gun and remove the screw.

CAUTION:The sensor plate mounting screw is secured with a locking sealant. If it is not heated prior to removal it make break!

4.

Remove the sensor plate.

5.

Clean the threads of the sensor plate screw bore with a (6 mm) tap.

6.

Reinstall the sensor plate.

7.

Adjust the sensor plate. Refer to ADJUSTMENT PROCEDURES for centering and height adjustment.

8.

Reinstall the stop bracket and air cleaner assembly.

Cold Start Injector > < Mixture Control Unit