38. Insert seal (8a) and shaped wedge (8b) in pressure plate (8).

Mount pressure plate (8) with the ground surface towards the cam insert.
Insert O-ring (4h) in bearing flange (A).

39. Insert bearing flange (4) in pump housing (2) and fasten with 4 bolts M8 (4b).

Tightening torque 25 Nm.

Note models 129.066/067, 140.04/050/051
Insert O-ring (2g) mount end cover (2k) and tighten with four bolts (arrow).
Tightening torque: 8 Nm.

Screw tandem pump (1) onto support (1a) with bolts (46). Screw on oil hose (arrow). Work step number 40 is omitted.