mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Fuel Distributor|Page 4595 > < Fuel Distributor|Page 4593
Page 3
background image

actuator.

Differential Pressure Valves

If a large basic injection quantity flows into the upper chamber, the diaphragm bends downwards and opens the outlet cross-section of the valve until the
set differential pressure is reached again. If the flow quantity drops, the valve cross section is reduced due to the equilibrium of forces at the diaphragm
until a pressure differential of 0.2 bar is again reached. This means that an equilibrium of forces exists at the diaphragm which can be maintained for
every basic injection quantity by controlling the valve cross section.

   