mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Idle Speed/Throttle Actuator - Electronic > < Fuel Tank Pressure Release Valve|Testing and Inspection
Page 2
background image

2.

Connect a suitable vacuum-pressure tester to port (B) of the breather valve and apply pressure.

^

The valve should open at approximately 30-50 mbar (0.435-0.725 psi.).  If not replace the breather valve.

3.

Apply vacuum to the breather valve.  

^

The valve should open at approximately 20-35 mbar (0.7-1 in. Hg).  If not replace the breather valve.

Idle Speed/Throttle Actuator - Electronic > < Fuel Tank Pressure Release Valve|Testing and Inspection