300TE (124.090) L6-3.0L (103.983) (1989)
3
Remove switch-off plunger (21) with pressure spring (24) and spring plate (25) from pump housing.
4
Remove O-ring (29).
5
Check all parts tor damage and wear. The gap between the two teflon rings (30, 31) must be completely close. If necessary insert the teflon rings
into the grooves with a little grease.