8

Set lever of level controller to "L" (emptying).

9

Run engine at idle. Set lever of level controller to "F" (filling), while paying attention to needle of pressure gauge.

10 The gas filling pressure of pressure reservoir is indicated when the needle of the pressure gauge rises continuously to a pressure value. This sudden

rise is effected by the oil pressure as soon as the oil pressure exceeds the gas pressure. Set lever of level controller to "L" (emptying). Stop engine.

11 Plug oil drain hose (061) on bleed screw (038n). Open bleed screw slowly and discharge pressure. Catch the oil in a clean vessel.

Checking Lefthand Pressure Reservoir

12 Connect test hose with lefthand pressure reservoir. Then perform jobs according to items 9 and 10.

13 Disconnect pressure tester. Mount bleed screw. Connect pressure lines to pressure reservoirs.