Shift Solenoid: Description and Operation

PURPOSE

The switchover valve (Y3/3) controls the vacuum to the control pressure cable element.

 
LOCATION

The switchover valve is located in engine compartment at driver side firewall.

OPERATION

The LH control unit controls the switchover valve. When the valve is energized, manifold vacuum reaches the pressure cable vacuum element and
delays the transmission upshift point. 

 