Condenser Fan: Description and Operation

Auxiliary Fans (M4m1 & M4m2)

PURPOSE:

-

The auxiliary cooling fans, which are located in front of the A/C condenser, provides additional air flow across the condenser and radiator to assist
during periods of high thermal load.

OPERATION:

-

All model 140 vehicles are equipped with two auxiliary fans. The current draw under operation in the 3rd stage is 35 amperes at 13 volts battery
voltage. The auxiliary fans are protected by a 30 ampere fuse in the maxi-fuse box F2.

Refrigerant Pressure Sensor [transmitter] (B12)

-

A refrigerant pressure sensor (B12) on the receiver-drier is installed in place of the two previous pressure switches.

Auxiliary Fan Relays (K9, K9/1, K30)