Page 3
background image

cut-off/ restart are shown in the chart. 

Maximum Engine RPM Function 

At excess RPM the fuel injectors are turned off to keep the engine from overrevving. The momentary engine RPM limit is 6300 ±50. After 10
seconds, the LH control module limits the engine to 6000 ±50 RPM.

Maximum Speed Function 

The maximum vehicle speed is limited to 210 km/h (130 mph). If this speed is exceeded, the air/fuel mixture is leaned out and the camshaft timing
is advanced. 

Self Adjusting Function

The ECU is adaptive to the changing engine operating parameters (wear and contamination of parts). It will adjust its calculations according to
assimilated input. Whenever the vehicle is started or driven, the ECU will use the value it has learned from the previous driving period.

Self Adjusting Oxygen sensor Function

The oxygen sensor (G3/2) operates in a similar fashion. It senses if the fuel mixture is rich or lean and the ECU adjusts the oxygen sensor control
accordingly. This self-regulating function keeps the air/fuel mixture at a constant midpoint. Therefore the need to adjust CO content is eliminated
and no more possible.

Safety Fuel Shut-off function

If due to a malfunction, the throttle valve opens further than the position called for by the accelerator pedal (cruise control not in operation), The
LH control module receives a signal and goes into a "limp home mode." This pre-programmed mode will set the fuel injection frequency (opening
duration) so the engine can't exceed 1100 RPM and the vehicle can be slowly driven to the repair shop.

Diagnostic Function

If the LH control module detects a specific fault more than 4 sequential times (ignition switch turned ON and OFF), a fault code is stored in the
control module memory. Only malfunctions which prevent/severely influence starting or operating of the fuel injection system are immediately
stored in the fault memory.

On California models, a "CHECK ENGINE" light will inform the operator of an emission related problem. It illuminates when a certain
malfunction in the engine management system is detected. The operator should bring the vehicle to the repair shop as soon as possible. 

The malfunction memory can be accessed via the diagnostic connector (X11/4). The malfunction memory is not erased when disconnecting the
battery.

Air Injection Control (Air)

In order for the catalytic converter to reach operating temperature as soon as possible, air from an air pump (125) is injected into the exhaust gas directly
behind the exhaust valves. The electronic clutch of the air injection is engaged by the LH control module via the air injection relay (K17). At the  same
time, the air injection pump switch-over valve is energized which applies vacuum to the air injection shut-off valve (126).

Air injection occurs after starting the engine at a coolant temperature between 10 °C (50 °F) and 40 °C (104 °F), an engine speed of less than 2500 RPM
and below a specified air mass. The air is injected for a maximum of 110 seconds depending on coolant temperature. The oxygen sensor control in
inactive during air injection.

Camshaft Timing Control

To improve the torque characteristics of the engine, the intake camshafts are "advanced" depending on engine speed and load.

The LH control module operates the camshaft timing adjuster solenoids (one per camshaft). When the solenoids are energized, the camshafts advance. In
"P" or "N" the adjustment is dependent on engine RPM only.

Engine speed:

Adjustment:

Up to 2000 RPM

Retarded

From 2000 - 4200 RPM

Advanced

From 4200 RPM

Retarded

Above 250 km/h (155 mph)

Advanced

Selector in "P" or "N"
up to 3000 RPM

Retarded 

Selector in "P" or "N"
from 3000 RPM

Advanced 

Charcoal Canister Purging Control (EVAP)

The fuel vapors stored in the charcoal canister are purged at temperatures above 70 °C (158 °F) via the purge switch-over valve (Y58/1). The vapors
then get burned in the combustion process. In order to control the purge quantity, the LH control module activates the switch-over valve at a frequency of

Ignition (EZL/AKR)|Page 3103 > < Ignition (EZL/AKR)|Page 3101