Air Door Actuator / Motor: Service and Repair

Removal and Installation of Vacuum Elements

Data:

Permissible leaking of vacuum elements 
-

20 mbar/min at 300 mbar vacuum

Plug-on length of connections 
-

10-12 mm

Special Tool:

Tester for vacuum Systems 
-

116 589 25 21 00

A. Vacuum Element For Center Nozzle

Removal:

1. Remove glove box.
2. Remove control unit.
3. Remove shutter center and loosen air connection hose to necessary extent.

4. Pull vacuum line from vacuum element (40).