mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Electrical Specifications|Page 4127 > < Electrical Specifications|Page 4125
Page 4
background image

6. Read off cold cranking amps and enter in tester.

Example: 12 V 46 Ah 420 cold cranking amps: -> 420 A. Confirm input with "Enter". The battery test starts after confirmation of the cold
cranking amps entry.
The test result or one of the following messages appears after approx. 15 s:
^

Test code -> Step 7

^

Vehicle model -> Step 9

^

Temperature > 0 °C /< 0 °C -> Step 10

^

Before charging / After charging -> Step 11

^

Surface voltage DETECTED (see above)

7. Read off test code with "Enter" and continue accordingly:

^

"Battery in good condition":
No further measures required.

^

"Charge and test":
Fully charge battery and retest (battery voltage > 12.4 V).

^

"Replace battery":
Replace battery if this message appears.

8. Print out test code and file in a tamperproof manner.

9. Follow the menu and select test mode:

^

Cars

^

Taxi

Electrical Specifications|Page 4127 > < Electrical Specifications|Page 4125