mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6038 > < Diagram Information and Instructions|Page 6036
Page 1
background image

Fuse Block: Diagnostic Aids

TROUBLESHOOTING TEST PROCEDURES

TESTING FOR VOLTAGE

 Voltage Check

1.

Connect one lead of a test light to a known good ground. When using a voltmeter, be sure the voltmeter's negative lead is connected to ground.

2.

Connect the other lead of the test light or voltmeter to a selected test point (connector or terminal).

3.

If the test light illuminates, there is voltage present. When using a voltmeter, note the voltage reading.

TESTING FOR CONTINUITY

 Continuity Check through a Switch

1.

Remove the fuse to the circuit involved.

2.

Connect one lead of a self-powered test light or ohmmeter to one end of the part of the circuit you wish to test.

3.

Connect the other lead to the other end of the circuit.

4.

If the self-powered test light glows, there is continuity. When using an ohmmeter, low or no resistance means good continuity.

TESTING FOR VOLTAGE DROP

Diagram Information and Instructions|Page 6038 > < Diagram Information and Instructions|Page 6036