600SEL (140.057) V12-6.0L (120.980) (1993)
Trunk / Liftgate Striker: Service and Repair
Replace And Adjusting Microswitch (Striker Eye Switch)
Preliminary work:
Trunk lid power locking removed. See: Trunk / Liftgate Latch/Service and Repair
Component Identification
Screw (10)
unscrew.
Cover (20)
unclip and remove with microswitch S88/3s1.
Reinstall in opposite order.
Adjust microswitch (after Installation)
Multimeter (01)
Connect according to drawing and set to acoustic continuity test.
Emergency actuation (30)
Actuate and press in striker eye (100).
Microswitch (S88/3s1)
Adjust against actuating lever (50) until acoustic signal sounds.
Emergency actuation (30)
Move back to vertical position.
Lever (60)
Pull toward microswitch, so that striker eye (100) slides upward and acoustic signal stops.
Perform function check.