600SEL (140.057) V12-6.0L (120.980) (1993)
4
If oil evacuation unit is not available, drain engine oil from oil pan (arrow); for this purpose remove engine compartment panelling at bottom.
Installation Note
Replace sealing ring on oil drain plug (arrow). Tighten drain plug (arrow) to 40 Nm.
5
Replace sealing ring (3).
6
Insert oil filter cartridge (4) into oil filter housing (5).
7
Install screw cap (2) and tighten to 20 Nm.
8
Install left air cleaner housing
9
Open cover (arrow), add engine oil. Allow engine to run and check for leakage.
10
Check oil level approximately 2 minutes after shutting off engine after warming up to operating temperature (arrow).
SPECIAL TOOLS