600SEL (140.057) V12-6.0L (120.980) (1993)
Diagnostic Impulse Display
1. Connect impulse counter based on the connection diagram.
-
U-Batt light diode in display field must light up.
2. Switch Ignition ON.
3. Press START button and hold for between 2 and 4 seconds.
-
Display 1 -no fault in system.
-