Compressor Pulley: All Technical Service Bulletins
A/C - Compressor Noise/Poor A/C Performance

Date: March 17, 2009

Order No.: P-B-83.55/119a

Supersedes: P-B-83.55/119 dated August 18, 2008

Group: 83

Revision History

Revision

Date

Purpose

a

3/17/09

Section I Revised / Note Added in Section II - No Cooling (Warranty Procedure)

-

8/18/08

Initial issue

SUBJECT:
All Model 203.040/740, Equipped with M271 Engine

Replacement of Refrigerant Compressor Belt Pulley Due to Noise Complaints or No Cooling

If you receive customer reports in the above model vehicles of noises at the refrigerant compressor, the cause could be a malfunctioning belt pulley or
belt pulley bearing. The pulley and pulley bearing can be diagnosed and replaced with the compressor still installed in the vehicle by following the
procedures below.

There may be no cooling due to the torque limiter in the drive hub of the pulley being sheared and the compressor not turning. Follow instructions for no
cooling starting with "Section II - No Cooling".

Section I - Noise Complaint

1. Test for alternator freewheel movement

1.1 If the alternator freewheel is NOT seized, continue with step 2.

1.2 If the alternator freewheel is seized, replace the alternator freewheel.

1.3 Check if the shaft for refrigerant compressor can be turned: Dismantle belt pulley for refrigerant compressor as per WIS document
AR83.55-P-7685. Carefully turn the compressor shaft, after dismantling the belt pulley, using a suitable socket.

^

If the shaft can be turned: Fit new belt pulley since the defective alternator freewheel damaged the limiter of the compressor pulley. Refer to WIS
document AR83.33-P-7685

^

If the shaft cannot be turned: Replace complete refrigerant compressor.

2. Noise diagnosis: 

Note:

If there is also a cooling performance complaint, the noise could be caused by low refrigerant level: Perform a Refrigerant Circuit Test as per SDS and
follow instructions for corrective actions.

3. Locate the noise by duplicating the conditions under which the complaint occurred.

4. Before the belt pulley on the refrigerant compressor is replaced, verify that the following components in the belt drive are not the source of the noise
and repair as required.

^

Alternator, Power steering pump, water pump 

Note:

Only for noise that is audible for both activated and deactivated air conditioning, continue with step 7.

If this condition does not occur: