The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off. The indicator lamp in the STH switch (N72s12 or S46) is
off. Malfunction shutoff is present.

To restart the heater after the fault has been rectified, the STH heater unit (except model 220) or the STH or HB [ZUH] heater unit (model 220) has to
be switched off and then on again using the STH switch (N72s12 or S46).

GF83.70-P-3066A Activate Heater With Stationary Heater Switch, Function

GF83.70-P-3066A Activate Heater With Stationary Heater Switch, Function

- with CODE (228) Stationary heater [models 203 up to 23.4.04, 209.3 up to 31.5.04, 215 as of 1.6.00 up to 31.8.02, 220 as of 1.6.00 up to 31.8.02,
230.4 up to 08]

Component Identification

Function requirements:

^

Circuit 15 OFF

Function sequence

1. The STH switch (N72s12 or S46) has been pressed for longer than 2 s and the "stationary heater On" signal has been activated.

2. The "stationary heater On" signal is forwarded straight to the STH control unit or the STH or HB [ZUH] control unit (A6n1).

Stationary Heater (STH) System|Page 9899 > < Stationary Heater (STH) System|Page 9897