Page 13
background image

-

No fire, sparks, naked flames or smoking.

-

Wear acid protection gloves, clothes and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2.1 Remove operating and display unit with control module

-

With CODE (352a) COMAND operating and display system

2.2 Remove radio
3

Remove stowage compartment below radio

NOTE:  When removing radio.

4

Remove sound-proofing measure

5

Unscrew screws (1)

NOTE:  Three screws.

-

See "Special Tools" given below.

6

Remove left vent flap actuator motor (M2/19) from AC housing (2)

7

Disconnect connector (3) from left vent flap actuator motor (M2/19)

8

Install in the reverse order

9

Synchronize left vent flap actuator motor (M2/19)

Special Tools

Torx bit set, P/N# 000 559 01 10 00

AR83.10-P-2011P Remove/Install Actuator For Right Vent Flap

AR83.10-P-2011P Remove/Install Actuator For Right Vent Flap

- with CODE (581) Comfort automatic air conditioning