mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13228 > < AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13226
Page 15
background image

Torx bit set, P/N# 000 559 01 10 00

AR83.10-P-2012P Remove/Install Actuator For Vent Flaps

AR83.10-P-2012P Remove/Install Actuator For Vent Flaps

- except CODE (581) Comfort automatic air conditioning

Shown on Model 203.0

DANGER:

-

Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Injury hazard and
danger of burning skin and eyes when handling battery acid or handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid protection gloves, clothes and goggles Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2.1 Remove operating and display unit with control module

-

With CODE (352a) COMAND operating and display system

2.2 Remove radio
3

Remove stowage compartment below radio

NOTE:  When removing radio.

4

Remove sound-proofing measure

5

Unscrew screws (1)

NOTE:  Three screws.

-

See "Special Tools" given below.