mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Stationary Heater (STH) System|Page 13274 > < Stationary Heater (STH) System|Page 13272
Page 22
background image

and

-

the control and operating module (N18, N22 or N22/7) is actuated via the CAN Class B (CAN B) with the "blower OFF" signal.

6

The control and operating module (N18, N22 or N22/7) switches the ventilation blower off and switches from stationary heating mode to normal
operating mode.

7

Malfunction delayed switch-off has finished:
-

The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off.

-

The green or red indicator lamp in the STH switch (N72s12 or S46) is extinguished.

Malfunction shutoff is present.

NOTE:  In order to restart, the STH heater or heater booster must be switched off and on again at the STH switch (N72s12 or S46) after the malfunction
has been remedied.

Stationary Heater (STH) System|Page 13274 > < Stationary Heater (STH) System|Page 13272