6

The interior temperature drops below the temperature value preset at the operating and control module (N18, N22 or N22/7).

7

The operating and control module (N18, N22 or N22/7) transmits the "Heat" signal to the STH or heater booster control module (A6n1) via the
CAN Class B (CAN-B).

8

Heater operation is restarted by the STH or heater booster control module (A6n1):
-

The green or red indicator lamp in the STH switch (N72s12 or S46) is switched back to steady light again.

9

After combustion has become stable, pre-heated air is again supplied to the interior via the vehicle blower.

NOTE:  During a heating period, repeated switch between stationary ventilation and heating can occur, depending on temperature behavior.

Terminate Heater Operation

Terminate Heater Operation, Function

The normal end of a heating operation, i.e. not initiated by a malfunction, is done following expiry of the maximum heating period specified in the STH
control module (A6n1).

NOTE:  The diagnosis system STAR DIAGNOSIS can be used to code the heating period for 10, 20, 30, 40, 50 or 60 minutes in the STH control
module (A6n1) for models 203, 209, 230 or the STH control module or heater booster (A6n1) for models 215, 220.

The STH switch (N72s12) on models 203, 209, 230 or the STH switch (S46) on models 215, 220 or the STH radio remote control transmitter (A8/3) can
be used to manually end heating operation in any phase of the heating period irrespective of the manner of actuation.

End Heater Operation During the Combustion Phase

End heater operation during the combustion phase, Function

Stationary Heater (STH) System|Page 13288 > < Stationary Heater (STH) System|Page 13286