5. The control and operating unit (N18, N22 or N22/7) switches off the blower motor and changes from the stationary heater mode to its standard
operating mode.
The duration of the heater run-on is dependent on the last active heating mode:
^
Partial load operation approx. 160 s
^
Full load operation approx. 170 s
6. Heater run-on is terminated.
The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off. The indicator lamp in the STH switch (N72s12 or S46) is
off.
GF83.70-P-3063C End Heater Operation During the Combustion Interval, Function
GF83.70-P-3063C End Heater Operation During The Combustion Interval, Function
- with CODE (228) Stationary heater [models 203 up to 23.4.04, 209.3 up to 31.5.04, 215 as of 1.6.00 up to 31.8.02, 220 as of 1.6.00 up to 31.8.02,
230.4 up to 08]