mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Charging System - Insufficient Charging|Page 5646 > < Charging System - Insufficient Charging
Page 2
background image

a)

There are no scorch marks or damage on the slip ring of the generator rotor (Figure 3, 1)

b)

Carbon brush length of defective regulator at least 5 mm (Figure 4, 1)

c)

Wear on the two brushes of the defective regulator is even (maximum 1 mm difference).

6.

Install new voltage regulator and tighten Phillips head screws to:

a.

(Figure 2, 2) = 2.0-2.4 Nm

b.

(Figure 2, 3) = 1.0-1.4 Nm.

7.

Install the plastic cover on the back of the generator and tighten the Phillips head screw (Figure 1, 2) to 2.2-2.6 Nm and the two nuts (Figure 1, 1)
as follows:

a.

Long stud 29.0-32.0 Nm

b.

Short stud to 11.0-13.0 Nm.

8.

Reinstall the repaired generator or the new generator in reverse order and verify proper operation as described in step 1.

Note:

Due to the several versions of alternator/generators used in production on all the above models, please refer to EPC for the correct voltage
regulator part number application. The correct part numbers may be found in group 15 and/or group 54 in EPC.

Note:

The following allowable labor operations should be used when submitting a warranty claim for this repair.

Charging System - Insufficient Charging|Page 5646 > < Charging System - Insufficient Charging