Voltage Regulator: Service and Repair

Remove/Install Regulator Of Generator

DANGER:
1.Lethal injuries are possible if vehicle slips off of lifting platform

-

Align vehicle between the columns of the lifting platform and position the four support plates at the lifting platform support points
specified by the vehicle manufacturer.

2.Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to
skin and eyes from battery acid or when handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid-resistant gloves, clothing and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery 

2

Remove generator (G2)

3

Unscrew collared nut (2)

4

Unscrew nut (3)

5

Unscrew cover bolt (4)

6

Remove cover (1)

7

Unscrew bolts (6) of regulator (6)

8

Remove regulator (5) towards the side

NOTE: Installation: Do not damage carbon brushes

9

Install in the reverse order