background image

AR83.10-P-2002P Remove/Install Actuator For Left Blend Air Flap

Shown on Model 203.0

1

Remove cover below instrument panel

NOTE:  Driver's side.

2

Unscrew screws (1)

NOTE:  Three screws.

-

See "Special Tools" given below.

3

Remove actuator motor for left blend air flap (M2/6) from AC/heater housing (2)

4

Disconnect connector (3) from actuator motor for left blend air flap (M2/6)

5

Install in the reverse order

6

Synchronize left blend air flap actuator motor (M2/6).

Special Tools

Torx bit set, P/N# 000 559 01 10 00

AR83.10-P-2003P Remove/Install Actuator For Right Blend Air Flap

AR83.10-P-2003P Remove/Install Actuator For Right Blend Air Flap