Stationary Heater (STH) System|Page 11837 > < Stationary Heater (STH) System|Page 11835
Page 45
background image

3. The STH control unit or the STH or HB [ZUH] control unit (A6n1) recognizes the cut-in signal, it activates the stationary heater menu in the

instrument cluster (A1) over CAN-B (CANB) and then simultaneously starts the heat or ventilate inquiry in the control and operating unit (N18,
N22 or N22/7).

4. The control and operating unit (N18, N22 or N22/7) compares the current interior temperature with the preset temperature value.

5.1. If the interior temperature is less than the preselected temperature value, the control and operating unit (N18, N22 or N22/7) sends the "heat"

signal over CAN-B (CAN-B) to the STH control unit or the STH or HB [ZUH] control unit (A6n1) and switches to the stationary heater mode.
The STH control unit or the STH or HB [ZUH] control unit (A6n1) actuates STH heater unit or STH or HB [ZUH] heater unit (A6) operation.
The indicator lamp in the STH switch (N72s12 or S46) indicates whether heater operation is active by flashing on and off.

5.2. If the interior temperature is higher than the preselected temperature value, the control and operating unit (N18, N22 or N22/7) sends the

"ventilate" signal over CAN-B (CAN-B) to the STH control unit or the STH or HB [ZUH] control unit (A6n1) and switches to the stationary
ventilation mode.
The STH control unit or the STH or HB [ZUH] control unit (A6n1) actuates the stationary ventilation and sends the "blower On" signal to the
control and operating unit (N18, N22 or N22/7). The indicator lamp in the STH switch (N72s12 or S46) displays the actuation of the stationary
ventilation by flashing on and off.

Circuit 15 ON

^

With the ignition switched on, a heat or ventilate inquiry is started in the control and operating unit (N18, N22 or N22/7) by the STH control unit
or the STH or HB [ZUH] control unit (A6n1) after heater operation has been actuated, as with the ignition switched off.

^

In this instance, the control and operating unit (N18, N22 or N22/7) monitors the STH control unit or STH or HB [ZUH] control unit (A6n1)
signal, it then always replies with the "heat" signal and then continues with its standard operating mode.

^

When the ignition is switched off and heater operation still active, the recorded signal induces an automatic change of mode for the control and
operating unit (N18, N22 or N22/7). The control and operating unit (N18, N22 or N22/7) then switches into the stationary heating or stationary
ventilation mode to match the interior temperature. It is no longer necessary for the signal to be issued again by the STH control unit or the STH or
HB [ZUH] control unit (A6n1).

GF83.70-P-3067A Switching Between Heating/Stationary Ventilation, Function

Switching Between Heating/stationary Ventilation, Function

- with CODE (228) Stationary heater [models 203 up to 23.4.04, 209.3 up to 31.5.04, 215 as of 1.6.00 up to 31.8.02, 220 as of 1.6.00 up to 31.8.02,
230.4 up to 08]

Stationary Heater (STH) System|Page 11837 > < Stationary Heater (STH) System|Page 11835