Illustrated On Model 202

1

Connect quiescent current retention device (7) as follows:
-

Connect positive lead terminal (+) to positive pole on battery.

-

Connect negative terminal (-) to battery ground (W10).

2

Switch on quiescent current retention device (7).

Component Identification, Part 1

3

Disconnect negative pole terminal (1) on battery.

4

Connect multimeter (2) as follows using "electrical connection set":
-

Connect positive (+) test cable to battery negative lead (1).

-

Connect negative (-) test cable to battery negative pole (3)