1
Connect quiescent current retention device (7) as follows:
-
Connect positive lead terminal (+) to positive pole on battery.
-
Connect negative terminal (-) to battery ground (W10).
2
Switch on quiescent current retention device (7).
Component Identification, Part 1
3
Disconnect negative pole terminal (1) on battery.
4
Connect multimeter (2) as follows using "electrical connection set":
-
Connect positive (+) test cable to battery negative lead (1).
-
Connect negative (-) test cable to battery negative pole (3)