background image

Fixed installation of charging socket in model 202 as of approx. 12/94

On the positive side the charging socket is connected to fuse block A of the fuse box in trunk (F4). The positive cable (cable color red/grey) can be
connected to receptacle C of fuses 1 to 6, terminal 30.

On the ground side (cable color, brown) the charging socket is connected to ground (right taillamp in trunk) (W7/1).

Fixed installation of charging socket in model 129

On the positive side (cable color, red/grey) the charging socket is connected to fuse 5, terminal 30 of the fuse box (F4) and on the ground side (cable
color, brown) to ground (right wheelhousing in trunk (W7).