C 280 (203.054) V6-3.0L (272.940) (2006)
-
No fire, sparks, naked flames or smoking.
-
Wear acid protection gloves, clothes and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.
1
Disconnect ground cable of battery
2.1 Remove operating and display unit with control module
-
With CODE (352a) COMAND operating and display system
2.2 Remove radio
3
Remove stowage compartment below radio
NOTE: When removing radio.
4
Remove sound-proofing measure
5
Unscrew screws (1)
NOTE: Three screws.
-
See "Special Tools" given below.
6
Remove left vent flap actuator motor (M2/19) from AC housing (2)
7
Disconnect connector (3) from left vent flap actuator motor (M2/19)
8
Install in the reverse order
9
Synchronize left vent flap actuator motor (M2/19)
Special Tools
Torx bit set, P/N# 000 559 01 10 00
AR83.10-P-2011P Remove/Install Actuator For Right Vent Flap
AR83.10-P-2011P Remove/Install Actuator For Right Vent Flap
- with CODE (581) Comfort automatic air conditioning