mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Stationary Heater (STH) System|Page 12641 > < Stationary Heater (STH) System|Page 12639
Page 31
background image

the STH switch (N72s12 or S46) goes out. The fault interlock is present, restarting the STH heater unit or the STH or HB [ZUH] heater unit is no
longer possible:

The malfunction lockout can be deactivated following the removal of the fault by interrupting the voltage supply (terminal 30). In order to achieve
this, activate heating mode with the STH switch (N72s12 or S46), withdraw and after approx. 10 s reinsert the corresponding fuse.

^

Model 203, 209
Fuse 35 in the interior fuse box

^

Model 215, 220
Fuse 41 in right fuse box

^

Model 230
Fuse 56 in the rear fuse and relay module

GF83.70-P-3054E Flame Failure/Flame Monitor Faulty During Heater Operation, Function

GF83.70-P-3054E Flame Failure/flame Monitor Faulty During Heater Operation, Function

- with CODE (228) Stationary heater [models 203 up to 23.4.04, 209.3 up to 31.5.04, 215 as of 1.6.00 up to 31.8.02, 220 as of 1.6.00 up to 31.8.02,
230.4 up to 08]