mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Campaign - ESP Module Ground Connection Inspection|Page 11773 > < Campaign - ESP Module Ground Connection Inspection|Page 11771
Page 3
background image

plug to the ESP Control Module connector.

8.

Install new heat shrink tubing onto ESP Control Module ground wire (thick wire), ensure that the heat shrink tubing stops where removed (A,
Figure 2), and does not cover crimped end.

9.

Place the 6 x 1.2 mm washer onto the ground stud at W16/3 (1 Figure 1).

10.

Install thin ground wires first, then reinstall the ESP ground wire (thick wire) and secure with the previously removed ground nut, observing
tightening torque of 10 Nm for the nut.

Parts Information

In Case of Warranty

Campaign - ESP Module Ground Connection Inspection|Page 11773 > < Campaign - ESP Module Ground Connection Inspection|Page 11771