mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10553 > < AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10551
Page 16
background image

6

Remove vent flaps actuator motor (M2/21) from heater/AC housing

7

Disconnect connector (3) from vent flaps actuator motor (M2/21)

8

Install in the reverse order

9

Synchronize vent flaps actuator motor (M2/21)

Special Tools

Torx bit set, P/N# 000 559 01 10 00

AR83.10-P-2013P Remove/Install Actuator For Activated Charcoal Filter Flap

AR83.10-P-2013P Remove/Install Actuator For Activated Charcoal Filter Flap

- with CODE (581) Comfort automatic air conditioning

Shown on Model 203.0

DANGER:

-

Risk of injury to skin and eyes suffering scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant.

-

Do not open cooling system unless coolant temperature is below 90 degrees C. Open cap slowly and release the pressure. Do not pour
coolant into beverage bottles.

-

Wear protective gloves, protective clothing and eye protection.

-

Risk of explosion from welding or brazing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant
vapors. Risk of injury from skin and eye contact with liquid refrigerant.

-

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear
eye protection and protective gloves. Work only in well ventilated areas. Do not carry out any repair work on the air conditioning system
circuit unless the system is drained.

CAUTION:  Protect air conditioning circuit and components from moisture when carrying out repair work.

AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10553 > < AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10551