The STH radio remote control receiver (A6/1) directly initializes the STH or heater booster control module (A6n1) with the signal "Stationary
heater ON" via the STH switch (N72s12 or S46).

5

The STH or heater booster control module (A6n1) recognizes the cut-in signal and starts the heat or ventilate inquiry in the operating and control
module (N18, N22 or N22/7) via the CAN Class B (CAN-B).

6

The operating and control module (N18, N22 or N22/7) activates, if present, its display field and compares the current in-car temperature with the
preset temperature value.

7.1 Interior temperature < preset temperature value:

-

The operating and control module (N18, N22 or N22/7) transmits the "Heat" signal to the STH or heater booster control module (A6n1) via
CAN Class B (CAN-B) and switches to stationary heating mode. The heat symbol is activated in the display field, if fitted.

-

The STH or heater booster control module (A6n1) initiates STH heater or heater booster (A6) operation.

-

The green or red indicator lamp in the emergency STH control switch (N72s12 or S46) indicates the fact that heater operation is active by
being permanently illuminated.

7.2 Interior temperature > preset temperature value:

-

The operating and control module (N18, N22 or N22/7) transmits the "Ventilate" signal to the STH or heater booster control module (A6n1)
via CAN Class B (CAN-B) and switches to stationary ventilation mode. If a display field is provided the fan symbol will be activated.

-

The STH or heater booster control module (A6n1) initiates stationary ventilation and transmits the "Fan ON" signal to the operating and
control module (N18, N22 or N22/7).

-

The green or red malfunction indicator lamp in the STH switch (N72s12 or 846) indicates that stationary ventilation is active by flashing on
and off.

NOTE:  Ignition (terminal 15) ON

-

With the ignition switched on, the STH or heater booster control module (A6n1) starts the heat or ventilate inquiry in the operating and control
module (N18, N22 or N22/7) after heater operation has been triggered, as it does with the ignition switched off.

-

In this case the control and operating module (N18, N22 or N22/7) picks up the STH or heater booster control module (A6n1) signal in the
back ground, always replies with the "Heat" signal and continues with its normal operating mode.

-

When the ignition is switched off and heater operation continues to remain active, the signal acquired in the back ground causes the operating
and control module (N18, N22 or N22/7) to change modes automatically. The module then switches to stationary heating or stationary
ventilation mode depending on the interior temperature. The output of a further signal by the STH or heater booster control module (A6n1) is
not therefore necessary.

Preprogrammed Activation of Heater Operation

Preprogrammed Activation Of Heater Operation, Function

Shown On Models 215, 220

Operating procedure