Page 8
background image

"hot"  = sufficient combustion --> heater operation continues.
"cold" = none or insufficient flame formation --> the STH or heater booster fuel metering pump (Y23) is switched off and a once only start repeat
is initiated.

9

Combustion has stabilized. The combustion air blower (A6m2) and the STH or heater booster fuel metering pump (Y23) continue to operate at
their maximum rotational speed and output. Heat exchange in the heat exchanger (2) commences.

10

Coolant temperature > 30 degrees C:
-

The STH or heater booster control module (A6n1) transmits the signal "Fan on" to the operating and control module (N18, N22 or N22/7) via
the CAN Class B (CAN-B).

-

The flow of hot air into the interior commences.

Switching Between Heating/Stationary Ventilation

Switching Between Heating/Stationary Ventilation, Function

Shown On Models 215, 220

Operating procedure

1

The STH heater or heater booster (A6) operates in partial load or full load mode:
-

The green or red indicator lamp in the STH switch (N72s12 or S46) illuminates.

-

The coolant heated in the STH or heater booster heater (A6) flows through the heating and cooling circuit.

-

Coolant temperature > 30 degrees C and < 72 degrees C:
The ventilation blower, initialized by the operating and control module (N18, N22 or N22/7), feeds pre-heated air into the interior.

2

The interior temperature exceeds the temperature value preset at the operating and control module (N18, N22 or N22/7).

3

The operating and control module (N18, N22 or N22/7) transmits the "Ventilate" signal to the STH or heater booster control module (A6n1) via
the CAN Class B (CAN-B).

4

The STH or heater booster control module (A6n1) initializes heater delayed switch-off to cool the STH or heater booster heater (A6) and to flush
the combustion chamber out:

NOTE:  The duration of the heater delayed switch-off is oriented towards the existing operating condition:
-

Partial load operation approx. 160 s

-

Full load operation approx. 170 s

5

The ventilation blower now feeds air into the interior without pre-heating.
-

The green or red malfunction indicator lamp in the STH switch (N72s12 or S46) indicates that stationary ventilation is active by flashing on
and off.

-

The in-car temperature falls or remains constant.