normal operating mode.

NOTE:  The duration of the heater delayed switch-off depends on the heater mode used last:
-

Partial load operation approx. 160 s

-

Full load operation approx. 170 s

6

The heater delayed switch-off has finished:
-

The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off.

-

The green or red indicator lamp in the STH switch (N72s12 or S46) is extinguished.

End Heater Operation During the Combustion Interval

End Heater Operation During The Combustion Interval, Function

Shown On Models 215, 220

Operating procedure

1

The STH or heater booster heater is then in the combustion interval:
-

The coolant circulation pump (A6m1) delivers the Coolant via the heat exchanger (2) and the heating and cooling circuits.

-

Coolant temperature > 72 degrees C and < 77 degrees C:
The ventilation blower, initialized by the operating and control module (N18, N22 or N22/7), feeds pre-heated air into the interior.

2

The end of heater operation is triggered
-

manually with the STH switch (N72s12 or S46),

-

manually with the STH radio remote control transmitter (A8/3)

or

-

independently by the STH or heater booster control module (A6n1) following the expiry of the maximum heating period.

NOTE:  The STH switch (N72s12 or S46) directly initializes the STH or heater booster control module (A6n1) with the signal "Terminate