mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Stationary Heater (STH) System|Page 10595 > < Stationary Heater (STH) System|Page 10593
Page 19
background image

-

The STH or heater booster fuel metering pump (Y23) and the combustion air blower (A6m2) deliver at their minimum speeds and outputs.

-

The heater element of the flame monitor heater element unit (A6r4) is switched on and resumes its function.

6.1 After the start attempt, which lasts for approx. 85 seconds, the glow pin is switched off, the flame monitor glow pin unit (A6r4) signals in its

function as flame monitor:
"hot" = flame present again - Combustion continues.
The STH or heater booster fuel metering pump (Y23) and the combustion air blower (A6m2) adjust their output and rotational speed to heat
requirements again.

6.2 Following the expiry of the 85 s long attempt at starting, the heater element is switched off, the flame monitor heater element unit (A6r4) reports in

its function as flame monitor:
"cold" = no flame formation
The STH or heater booster control module (A6n1) triggers a heater malfunction delayed switch-off with subsequent malfunction shutoff for 
approx. 120 s.

The STH or heater booster fuel metering pump (Y23) is switched off and the operating and control module (N18, N22 or N22/7) is actuated via
the CAN class B (CAN-B) with the signal "Fan off".
-

The control and operating module (N18, N22 or N22/7) switches the vehicle blower off and switches from stationary heating mode to normal
operating mode.

The malfunction delayed switch-off has finished:
-

The combustion air blower (A6m2) and the recirculation pump (A6m1) are switched off.

-

The green or red indicator lamp in the STH switch (N72s12 or S46) is extinguished.

Malfunction shutoff is present.

NOTE:  In order to restart, the STH heater or heater booster must be switched off and on again at the STH switch (N72s12 or S46) after the malfunction
has been remedied.

Under/Overvoltage During Heater Operation

Under/overvoltage During Heater Operation, Function

Stationary Heater (STH) System|Page 10595 > < Stationary Heater (STH) System|Page 10593