Page 1
background image

Condenser HVAC: Service and Repair

Installing, removing condenser

DANGER:

-

Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated 
refrigerant vapors. Risk of Injury from skin and eye contact with liquid refrigerant.

-

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear
eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit
only after the system has been discharged.

CAUTION:  Protect air conditioning circuit and components from moisture when carrying out repair work.

1

Remove drier cartridge

CAUTION:  Installation:  after the refrigerant circuit is opened replace drier cartridge.

-

Observe additional oil quantity after replacing parts