Electrode (inner)

Electrode (outer)

Heating element 

Inner, open combustion chamber 

Protective tube 

View of electrical connection for O2sensor 
1  Sensor heater 
2  Sensor heater ground 
3  O2 sensor signal ground 
4  O2 sensor signal 

G3/1 

O2 sensor downstream of TWC

G3/2 

O2 sensor upstream of TWC

G3/3 

Left O2 sensor upstream of TWC

G3/4 

Right O2 sensor upstream of TWC 

G3/5 

Left O2 sensor downstream of TWC

G3/6 

Right O2sensor downstream of TWC

Voltage-free insulated O2 sensors are used.
The active sensor ceramic consists of a gas-permeable ceramic body manufactured from zirconium dioxide. A protective tube with several slots protects
the ceramic body from mechanical stresses and from temperature jumps.
The eletrical connection is performed by means of a 4-pin connector.   
The capacity of the sensor heater at operating temperature is:
- 18 W (engines with ME 1.0, 2.0, 2,1)
- 7 W (engine 112, 113 with ME 2.8, engine 137). 

Planar Sensor

O2 Sensors, Design
Planar Sensor

 

PTFE moulded hose 

PTFE grommet 