Instrument Panel Control Module: Customer Interest
Instruments - Analog Gauges Inoperative After Start Up

INSTRUMENT CLUSTER: ANALOG POINTERS NONFUNCTIONAL AFTER VEHICLE IS STARTED

Topic Number

LI54.30-P-047526

Version

1

Design Group

54.30 Instrument cluster/display instruments/warning devices

Date

07-31-2009

Validity

Model 204 with code 442 (comfort multifunction steering wheel) up to VIN...A 301923 / ...F 359835 / ...R 085568
Model 207 up to VIN ...F 002191
Model 212 up to VIN ...A 016686

Reason for change

Remedy added/superceded DTB S-B-54.30/222

Reason for block 

COMPLAINT:

With the named vehicles, all analog pointers in the instrument cluster (A1) may not be functional for approx. one to two minutes after the engine is
started. Full functionality is then restored.

NOTES:

The fault code occurs at low temperatures in particular.

CAUSE:

Fault during synchronization phase of pointers in instrument cluster (A1).

REMEDY:

Program new software for instrument cluster (A1) A2049023401 (model 204) or A2044423021 (model 207, 212) or higher.

NOTE:

The required software is available as of the following Xentry diagnostics versions:

Model 204 as of 06/2009

Model 207 as of 05/2009

Model 212 as of 02/2009.

Symptoms

Instruments - Analog Gauges Inoperative After Start Up|Page 16486 > < Instruments - Navigation Instructions NOT Displayed|Page 16481